PLDD
CONTACT US

Low level laser therapy through the equine tendon in vivo

Keywords:laser, fibers, surgical,  Time:02-12-2015
Introduction

Low level laser fibers therapy (LLLT) is a popular modality in the physiotherapeutic management of human and animal patients. LASER (‘light amplification by the stimulated emission of radiation’) differs from ordinary light in its unique properties of monochromacity (single wavelength), coherence (waves in phase) and collimation (waves in parallel). As a result, it can deliver large amounts of energy to a small region over a short period of time (Kitchen and Partridge, 1991; Low and Reed, 2000). The use of low powered surgical laser fibers(<500mW, <35J/cm², typical wavelengths of 600-1300nm) in the management of pain, wound healing and soft tissue injury was developed in the 1960s and has grown steadily since (Baxter, 2002). Low level laser therapy is believed to have photochemical rather than thermal effects because low irradiation levels are used and no appreciable temperature rise takes place (Kitchen and Partridge, 1991). The photochemical theory, which is not yet universally accepted, postulates that the absorbed light interacts with chromophores (organic molecules) which in turn modulate cellular activities (Beckerman et al., 1992; Chartered Society of Physiotherapists, 1998; Baxter, 1999). Research, therefore, centres on the cellular effects of laser as well as the effects that lasers have on wound healing, pain and musculoskeletal conditions. Cellular research has demonstrated that LLLT reduced experimentally induced inflammation by 20-30% and that wavelengths of 660, 820 and 870 nm encouraged macrophages to stimulate fibroblast proliferation (Young et al., 1989; Honmura et al., 1992).
Clinically, LLLT is perceived as effective in the acceleration of wound healing (Baxter et al., 1991). A meta-analysis (Beckerman et al., 1992) and a Cochrane review (Flemming and Cullum, 2003) drew no conclusions regarding the efficacy of LLLT in skin disorders and venous leg ulcers respectively. Controlled trials on animal wounds treated with laser revealed varying degrees of success (Kaneps et al., 1984; Fretz and Li, 1992; Lucroy et al., 1999; Petersen et al., 1999). Two recent studies reported pain relief in both RA (rheumatoid arthritis) and fibromyalgia patients post irradiation with LLLT while a meta-analysis established no effect (Gam et al., 1993; Brosseau et al., 2003; Gur et al., 2003). In the equine model, Martin and Kilde (1987) demonstrated the alleviation of back pain in a non-controlled study. Finally, a Cochrane review of the use of 904nm laser in musculoskeletal conditions concluded that LLLT appeared effective for pain relief and quicker functional recovery (de Bie et al., 1996). Sharma et al. (2002) displayed an ultrasound assessed decrease in tendon diameter of tenosynovitis diagnosed tendons, after laser application. Laser was no more effective than glycosaminoglycan or conservative management in treating superficial flexor tendon injuries in racehorses (Marr et al., 1993).

It is difficult to compare results of the various studies into laser therapy as parameters, when fully recorded, often vary (Kitchen and Partridge, 1991; Baxter, 2002). Different conditions are treated, different dosages utilised and different outcome measures are recorded. Investigative findings are ambiguous. For practically every supportive trial, there is a contradictory counterpart. Laser appears a popular therapy lacking sufficient supportive research (Vasseljen et al., 1992; Gam et al., 1993; Saunders, 1995). However, as Basford (1989) states, there exists enough evidence to justify the continued investigation of this mode of therapy. Practising physiotherapists surveyed corroborated the beneficial clinical effects of LLLT (Baxter, 1991). The recent extension of FDA (Federal Drug Agency, USA) approval to LLLT also illustrates this (Baxter, 2004).
As previously mentioned, penetration depth is one of the uncertainties pertaining to laser parameters. It is accepted and proven that penetration depth is a wavelength dependent property. Longer wavelengths will penetrate further (Kolari, 1985; Kolarova et al., 1999; Enwemeka, 2003). As a result, visible red laser light is used to treat wounds while infrared laser light is used for deeper musculoskeletal conditions. Nevertheless, energy density applied to the target tissues is unknown as the result of uncertainties pertaining to penetration depth (Low and Reed, 2000). Irradiation levels, in the form of energy density (J/cm²) at the surface applied, are commonly recorded by the clinician (Beckerman et al., 1992; Baxter, 1999). When LLLT is used in veterinary medicine, depth of penetration through hair and pigment is a major issue (Martin and Kilde, 1987; Bromiley, 1993; Marr et al., 1993; Petersen et al., 1999; Ramey and Basford, 2000). Currently, it is recommended that the irradiated area should be clipped and cleaned with an alcohol wipe before treatment (Bromiley, 1993; Low and Reed, 2000). In conclusion, many questions remain unanswered regarding LLLT, including optimal dosimetry, mode of action, and number of treatments required etc. This study was undertaken in an attempt to address one of the above questions i.e., to what extent laser penetration in the equine model is affected by cleaning and clipping the area of application.

Materials and methods

Subjects were recruited from the resident equine population at the Hawkshead campus of the Royal Veterinary College, London. Permission was obtained from the relevant animal guardian. Horses with a history of, or obvious evidence of, forelimb tendon pathology were excluded. In all, seventeen sets of data were collected from the forelimbs of nine horses (one set of incomplete data was excluded).Three of the horses were grey, while the rest were bay. Five of the horses were thoroughbred (TB) while the rest were Irish Draught/TB crosses.

The laser therapy system used was a Thor DDII unit (Thor International Ltd, Amersham, Bucks, UK). A single point GaAlAs (gallium aluminium arsenide) laser probe, emitting a continuous beam of wavelength 810nm and power 500mW, was used. In compliance with safety measures, the investigator and assistant wore protective goggles to prevent inadvertent ocular damage (Chartered Society of Physiotherapy, 1991; 1998). The light sensor used was a M3000 (FOE Ltd, Argyll, UK). This sensor was capable of detecting light waves in the 600-1300nm wavelength and gave readings in microwatts x 10 (uWx10). This was precalibrated by the manufacturer. A standard vernier caliper (Mitutoyo (UK) Ltd, Hampshire, UK) was used. These calipers possess an accuracy of 0-200mm+/-0.03mm and a graduation of 0.02mm/0.001.
Alcohol solution was used to clean the horses’ coats. It was also used to clean the horses’ skin after clipping. Electric clippers (number 30 blades) were used to clip the horses’ skin. A preliminary study tested light penetration through the tendons of six subjects. These were tendons of varying thickness and coat colour. Results indicated that the light sensor was sensitive enough to detect changes in penetration of light through various equine tendons. It also suggested that the readings should be taken after sunset to minimise ambient light. Each horse was restrained with a head collar and lead rope in a loose box with an attendant and some loose hay. Measurements were conducted with the animal either standing on a rubber mat or a shallow bed of shavings and with the animal standing as ‘square’ as possible i.e., equal weight bearing on all four legs. Tendon lateromedial dimensions were gauged using the vernier calipers. This was measured at the junction of the distal third and proximal two-thirds of the superficial digital flexor tendon (SDF) as this is an easily identifiable site and is a frequent site of tendon injury (Kaneps et al., 1984). The therapeutic laser probe was applied at the medial aspect of the SDF of the horse’s forelimb, at the junction of the distal third and proximal two thirds. This was done using the contact technique: firmly, perpendicular to the skin with slight indentation of the skin and by the same investigator each time (Baxter, 1994).The light sensor was then held in contact, directly opposite the laser probe, on the lateral aspect of the SDF. The two were maintained in position until the sensor delivered a reading. This was repeated three times and the mean measurement recorded.was by multiway analysis of variance with ‘light transmitted’ as the dependent variable and colour (grey or bay), horse, leg (right or left) and condition (dry, alcohol wet, alcohol dry, clipped dry or clipped wet) as the independent variables. The variable ‘leg’ was nested in the variable ‘horse’ and the variable ‘horse’ was nested in the variable ‘colour’. All significance tests were two sided (Petrie and Sabin, 2000).

Results

Simple cleaning of the hair and skin surrounding the tendon with alcohol, caused a general increase in penetration of light through the tendons (p=0.5762) (Figure 1, see p277). Readings which failed to register on the light sensor (i.e., those which produced a reading of 0) would indicate that the laser light introduced had been completely absorbed by the tendon and that none of this light had penetrated to the other side.